CPVAN Radio Interlinked Smoke and Heat Alarms with Remote Control Suitable for Scottish Regulations Fire Detector with Battery
Heat Alarm with Wireless Interlink
This HD11 heat alarm interlinked with SM11R smoke alarm unit which both with 10 year sealed lithium battery incorprates the following feathers:Sealed in high performace battery service life of 10 years.Alarm Silence feature allows unwanted alarms to be silenced resets automatically.It's ideal most suitable for kitchens,boiler rooms,workshops and garages where dirt and dust contaminate smoke alarms causing nuisance alarms.Once the alarm detects fire it signals to all connected alarms to raise alarms across the entire building.Loud 85 decibel horn.Class A1.Kitemark to BS5446-2 2003.CE Mark
Operation Guide
1.Long press the button 10 seconds until hear one "beep"
2.Test --Press one time
3.Paring--Choose one alarm and press 4 times rapidly,then press others 2 times rapidly.
4.Unbind--Press rapidly the alarm you want 2 times.
Refer to the manual for details.
LED Indicators
1.Normal status: Red LED Flashes once every 60 seconds.
2.Test status: Red LED flashes once every second.
3.Hush/Silence mode: Red LED flashes once every 8 seconds.
4.Low Battery status: Red LED flashes once every 60 seconds and 1 beep every 60 seconds.
5.Fault status: the alarm will deliver beeps every 40 seconds.
Silence Mode
During the unit is alarming, you can push the test button, it will be paused the unit alarming for approx 10 minutes. The red LED will flash once every 8 seconds, it indicates the smoke alarm device is running into the silence mode.The silence feature is to be used only when a known alarm condition, such as smoke from cooking activates the alarm.The smoke alarm device will automatically reset after approximately 10 minutes, if after this period, particles of combustion are still present, the alarm will sound again.
Specifications:
Power: DC 2*1.5V AA
Alkaline or Carbon Zinc battery
Battery Package: Alkaline (LR6,MN1500) or Carbon Zinc battery (R6P)
Operation Current: <15uA (standby); <70mA (alarm)
Alarm Volume: >85 dB(A) at 3 meters
Alarm Sensitivity: 0.09 - 0.17 dB/m
Low Battery: 2.6 ± 0.1 V
Silence Time: approx. 10 minutes
Comply to Standard EN14604:2005/AC:2008
Trouble Shooting
Problem |
Method of disposal |
The alarm does not sound when testing |
Please check whether the batteries be well assembled according tothe Guide required |
Red LED flashes and the alarm delivers one beep every 60 seconds |
The battery is low. Please replace the batteries as soon as possible. |
The alarm delivers one beep every 40 seconds |
1.clean the alarm. Please refer to the "maintenance and cleaning" section. |
2.the alarm is malfunctioning. Contact the retailer to replace it. |
|
Nuisance alarms triggered intermittently or when residents are cooking, taking showers, etc. |
1.press silence button. |
2.clean the alarm. Please refer to the "maintenance and cleaning" section. |
|
3.move the alarm to new location. |
|
The alarm does not triggered when other alarm be triggered |
1.check the device if be interlinked. |
2. check the distance between the interlinked alarms out of max allowed distance |
- Brand Name
- CPVan
- Origin
- Mainland China
- Model Number
- SM11R+HD11+RC
- Type
- Smoke Detector
- Certification
- CE
- Smart home platform
- NONE
- Frequency
- 433 MHZ Interconnection
- Voice Volumn
- 85DB
- Alarm Sensitivity
- 0.09-0.17 dB/m
- Heat Sensitivity
- 54-70℃
- Working distance
- Up to 100m(Outdoor open)
- Interlinked devices
- Max 30pcs per group
- Comply to Standard
- EN 146042005/AC2008&BS5446-22003
- Alarms Suitable for Scottish Regulations
- Radio-Interlinked
- smoke detector
- interlinked smoke and heat alarms
- security protection
- smoke alarm
- fire
- interlinked smoke alarms
- heat alarm
- interlinked smoke and heat detector lithium
- wirelessinterlinked smoke and heat alarm
- interlinked smoke and heat detector
- linked smoke detectors
- heat detector
- interlink heat detector
- wireless smoke detector
- homekit smoke detector
- fire alarm system